Sensra · Observe

ψN 0.00 · Sensra

The live plasma state, reconstructed from every diagnostic.

No single diagnostic sees the whole plasma. Sensra fuses them into one state estimate every control cycle, with an honest error bar, and tells Plasmara when the twin has drifted.

Example state estimate

Elongation κ
1.74 ± 0.02
Vertical position
+0.6 ± 0.3 cm
q95
3.42 ± 0.08
βN
2.06 ± 0.11

Illustrative values for an example device.

ψN 0.14 · Capabilities

What Sensra does.

Fusion

Multimodal fusion

Magnetics, interferometry, Thomson, ECE, bolometry and more in one estimate.

Edge

Control-rate output

Runs on Holoscan beside the device at control-cycle rates.

Uncertainty

Honest error bars

Every quantity carries its uncertainty, so Stellix and Quenra know what to trust.

Drift

Twin recalibration

Flags when the twin and the plasma disagree, and by how much.

Cleaning

Denoise and repair

Detects failed channels and fills gaps from the twin, marked as filled.

Replay

Archive mode

Run the same estimator over past campaigns for analysis.

ψN 0.29 · Diagnostics

Every sensor in, one state out.

MagneticsFlux loops, pick-up coils≤ 10 kHz
InterferometryLine-integrated density≤ 10 kHz
Thomson scatteringElectron temperature and density≤ 1 kHz
ECEElectron temperature≤ 100 kHz
BolometryRadiated power≤ 10 kHz
Soft X-rayCore MHD activity≤ 100 kHz
SpectroscopyImpurities, rotation≤ 1 kHz
CamerasEdge and divertor view≤ 1 kHz

Sensra state estimate · every control cycle

Shape, position, current profile, βN, q95, with uncertainty
Example

Diagnostic families and typical sampling ceilings we plan to support first. Rates are illustrative; every device is different.

ψN 0.43 · How it works

How Sensra runs.

  1. 01Week 1

    Map

    Diagnostics mapped to the device model.

  2. 02Weeks 2–5

    Train

    Estimator trained on archive and twin data.

  3. 03Week 6

    Replay

    Run over recorded shots; compare with your reconstruction.

  4. 04After review

    Stream

    Live at the edge, in shadow first.

ψN 0.57 · Specification

Planned specification.

Sensra specification (draft)
ItemPlanStatus
InputsMagnetics first; profiles and imaging added per deviceFirst
OutputsShape, position, current, βN, q95, profiles, each with uncertaintyFirst
LatencyUnder 1 ms per estimate at the edgeDesign target
HardwareIGX/Jetson with Holoscan; TensorRT servingPlanned
FallbackMarks degraded estimates; never hides a failed channelFirst
InterfacesHoloscan operators, IMAS IDS, REST for replayFirst

ψN 0.71 · In the loop

Where Sensra sits.

Sensra is the eyes of the loop: it feeds Stellix and Quenra, and recalibrates Plasmara after every shot.

Plasmara is the twin in the middle. Sensra keeps it honest against live diagnostics, Stellix trains control inside it, Quenra bounds every policy, and Synthos generates the rare shots none of them can wait for.

ψN 0.86 · Questions

Straight answers.

Does Sensra replace our equilibrium reconstruction?

No. It learns from your reconstruction and runs at control rates; your reconstruction stays the reference.

What if a diagnostic fails mid-shot?

Sensra marks the channel, widens the uncertainty and tells Quenra. It does not invent a clean signal.

Which diagnostics first?

Magnetics, then interferometry, ECE and Thomson. Others are added per device.

ψN 1.00 · Next step

Send us one campaign of shots. Get a calibrated twin back.

Share device geometry, coil and actuator limits, and the diagnostics from a recent campaign. We fit a Plasmara twin to it, replay your shots, and show where control and disruption avoidance could move first.