ψN 0.00 · Platform
One twin per device. Everything else runs against it.
Six layers, from a device description to a policy on the actuators. Each layer is an API, so a program can start with the twin and add control later.
ψN 0.17 · Architecture
Six layers, one device model.
| Layer | What it does | Runs on |
|---|---|---|
| 1 · Device model | Geometry, coils, actuators, diagnostics and limits as one description | Any |
| 2 · Plasma twin | Plasmara physics-ML plasma and MHD surrogates, calibrated per device | DGX/HGX, Modulus, CUDA |
| 3 · State estimation | Sensra fuses diagnostics into a live plasma state with uncertainty | Holoscan, IGX/Jetson |
| 4 · Control training | Stellix RL policies trained under domain randomization | DGX/HGX, Isaac method |
| 5 · Guardrails | Quenra disruption prediction and the safe envelope around every policy | TensorRT, Triton |
| 6 · Copilot and feedback | Scenario exploration, explanations; each shot recalibrates the twin | NeMo, Omniverse |
ψN 0.33 · The loop
Five products that sharpen each other.
Plasmara is the twin in the middle. Sensra keeps it honest against live diagnostics, Stellix trains control inside it, Quenra bounds every policy, and Synthos generates the rare shots none of them can wait for.
ψN 0.50 · Deploy
Where it runs.
First
Fusalis cloud
Hosted GPU capacity for twin fitting, sweeps and training. The fastest start.
Planned
On premises or air-gapped
For programs with sensitive data. NVIDIA AI Enterprise stack on your hardware.
Planned
At the device
Sensra and Quenra on IGX or Jetson-class hardware beside the control system.
ψN 0.67 · Control
Your team sets how far it goes.
- L0Replay
Fusalis runs against recorded shots only. Nothing touches the device.
- L1Shadow
Live estimates and recommendations, next to your plasma control system. Operators decide.
- L2Bounded
A Stellix policy controls named actuators inside a Quenra envelope you approve, with your PCS as fallback.
- Your PCS stays the fallback at every level.
- Every policy runs in the twin before it runs on the device.
- Every action has a named approver and an audit entry.
- Drop back to replay with one switch.
ψN 0.83 · Security
Device data stays with the program.
Isolation per program
Each device and program has its own twin, keys and storage.
Export-control aware
Data residency and access lists set per program, ready for review by your compliance team.
Signed models
Every twin and policy version is signed, so you know exactly what ran on which shot.
ψN 1.00 · Next step
Send us one campaign of shots. Get a calibrated twin back.
Share device geometry, coil and actuator limits, and the diagnostics from a recent campaign. We fit a Plasmara twin to it, replay your shots, and show where control and disruption avoidance could move first.